When upgrading your consumer unit (fuse box), you'll face a key decision: individual RCBOs per circuit, or a split-load board with shared RCDs? Both meet regulations, but one gives significantly better protection and convenience. Here's our honest electrician's comparison.
| Feature | RCBO Consumer Unit | RCD Consumer Unit (Split-Load) |
|---|---|---|
| Protection Level | Individual protection per circuit | Shared protection across circuit groups |
| Nuisance Tripping | Only affected circuit trips | Half the house can lose power |
| Fault Finding | Instantly know which circuit has the fault | Must test each circuit to find fault |
| Cost | £400–£700 (board + RCBOs) | £250–£450 (board + RCDs + MCBs) |
| Freezer/Fridge Safety | Stay on if another circuit faults | May lose power — food spoilage risk |
| Alarm/CCTV | Stay on if another circuit faults | May lose power — security gap |
| 18th Edition Compliance | Fully compliant — exceeds requirements | Compliant if correctly configured |
| Future Expansion | Easy — add individual RCBOs | May need to rebalance RCD groups |
| Installation Time | Similar | Similar |
| Professional Recommendation | Industry standard for new work | Acceptable for budget upgrades |
Protection Level
RCBO Consumer Unit
Individual protection per circuit
RCD Consumer Unit (Split-Load)
Shared protection across circuit groups
Nuisance Tripping
RCBO Consumer Unit
Only affected circuit trips
RCD Consumer Unit (Split-Load)
Half the house can lose power
Fault Finding
RCBO Consumer Unit
Instantly know which circuit has the fault
RCD Consumer Unit (Split-Load)
Must test each circuit to find fault
Cost
RCBO Consumer Unit
£400–£700 (board + RCBOs)
RCD Consumer Unit (Split-Load)
£250–£450 (board + RCDs + MCBs)
Freezer/Fridge Safety
RCBO Consumer Unit
Stay on if another circuit faults
RCD Consumer Unit (Split-Load)
May lose power — food spoilage risk
Alarm/CCTV
RCBO Consumer Unit
Stay on if another circuit faults
RCD Consumer Unit (Split-Load)
May lose power — security gap
18th Edition Compliance
RCBO Consumer Unit
Fully compliant — exceeds requirements
RCD Consumer Unit (Split-Load)
Compliant if correctly configured
Future Expansion
RCBO Consumer Unit
Easy — add individual RCBOs
RCD Consumer Unit (Split-Load)
May need to rebalance RCD groups
Installation Time
RCBO Consumer Unit
Similar
RCD Consumer Unit (Split-Load)
Similar
Professional Recommendation
RCBO Consumer Unit
Industry standard for new work
RCD Consumer Unit (Split-Load)
Acceptable for budget upgrades
An RCBO (Residual Current Breaker with Overcurrent protection) combines the function of an MCB and RCD in one device. Each circuit gets its own RCBO, meaning each circuit is individually protected against both overload and earth faults. If one circuit trips, everything else stays on.
Ideal for: All new consumer unit installations, full rewires, homes with freezers or security systems, properties with frequent tripping issues, and anyone wanting the best protection available.
A split-load RCD board divides your circuits into two groups, each protected by a shared RCD. Individual MCBs (Miniature Circuit Breakers) protect against overload, while the RCDs protect against earth faults. If an earth fault occurs on any circuit in a group, the RCD trips and all circuits in that group lose power.
Ideal for: Budget-conscious upgrades from very old fuse boxes, rental properties where cost is the primary concern, or as a stepping stone before a future RCBO upgrade.
We install RCBO boards as standard on all new installations and upgrades. The extra £100–£200 cost is worth it for the dramatically reduced nuisance tripping alone. With an RCBO board, a fault on one circuit only trips that circuit — your fridge, freezer, alarm, and other circuits stay on. With a split-load RCD board, a single fault can kill power to half your home. For new builds and full rewires, RCBO boards are the professional standard in 2026.